FiberForce® Structural Plastic Lumber

 

                                                                English Units                              Metric Units

Test

ASTM Test

Value

Units

Value

Units

Flexural Strength

D6109-97

2750

PSI

193

Kg/cm2

Flexural Modulus

D6109-97

306080

PSI

21520

Kg/cm2

Compression Strength

D6108-97

2340

PSI

165

Kg/cm2

Compression Modulus

D6108-97

114900

PSI

8077

Kg/cm2

Specific Gravity

D6111-97

0.93

g/cc

0.93

g/cc

Flash point

 

644

Deg F

340

Deg C

Moisture Absorption

 

0.06

% by Weight

0.06

% by Weight

Thermal Expansion

D6341-98

0.000033

Inch/Inch/Deg F

 

 

Average Nail pull out

D6117-97

504

Lbs

229

Kg

Static coefficient of Friction -Dry

D2394-83(99)

.53

 

 

 

Static coefficient of Friction -Wet

D2394-83(99)

.51

 

 

 

Sliding coefficient of Friction -Dry

D2394-83(99)

.23

 

 

 

Sliding coefficient of Friction -Wet

D2394-83(99)

.51

 

 

 

Flame Spread

E84(03a)

62

 

 

 

Flame Spread Classification

E84(03a)

60

 

 

 

Smoke Developed

E84(03a)

230

 

 

 

Smoke Developed Classification

E84(03a)

250

 

 

 

Spontaneous Ignition

D-1929

824

Deg F

440

Deg C

 

This data represents average values NOT Minimums. Safety factors must be added in to the design.

 

Chemical Resistance

High-density polyethylene has a high resistance to most acids and chemicals.  Bedford Plastic Lumber is not affected by exposure to most Substances.

 

Ultraviolet Weathering

An ultraviolet stabilizer is incorporated at the time of manufacture. It protects the plastic from ultraviolet light degradation and ensures that the outside of the product will not degrade in exterior applications.

 

 

 

 

 